<?xml version="1.0" encoding="UTF-8"?>
<!DOCTYPE ArticleSet PUBLIC "-//NLM//DTD PubMed 2.7//EN" "https://dtd.nlm.nih.gov/ncbi/pubmed/in/PubMed.dtd">
<ArticleSet>
<Article>
<Journal>
				<PublisherName>دانشگاه تبریز</PublisherName>
				<JournalTitle>دانش کشاورزی وتولید پایدار</JournalTitle>
				<Issn>2476-4310</Issn>
				<Volume>36</Volume>
				<Issue>1</Issue>
				<PubDate PubStatus="epublish">
					<Year>2026</Year>
					<Month>04</Month>
					<Day>20</Day>
				</PubDate>
			</Journal>
<ArticleTitle>Evaluation the effect of soil moisture on the performance and the efficiency of an open or closed loop geothermal system in a sample greenhouse</ArticleTitle>
<VernacularTitle>تاثیر رطوبت خاک بر عملکرد و راندمان سامانه زمین‏ گرمایی در دو حالت حلقه باز و بسته در سرمایش گلخانه</VernacularTitle>
			<FirstPage>169</FirstPage>
			<LastPage>181</LastPage>
			<ELocationID EIdType="pii">21388</ELocationID>
			
<ELocationID EIdType="doi">10.22034/saps.2024.61526.3217</ELocationID>
			
			<Language>FA</Language>
<AuthorList>
<Author>
					<FirstName>ابوالفضل</FirstName>
					<LastName>هدایتی پور</LastName>
<Affiliation>گروه مهندسی بیوسیستم، دانشگاه شهید چمران اهواز</Affiliation>

</Author>
<Author>
					<FirstName>محسن</FirstName>
					<LastName>سلیمانی</LastName>
<Affiliation>گروه مهندسی بیوسیستم، دانشگاه شهید چمران اهواز</Affiliation>

</Author>
<Author>
					<FirstName>مصطفی</FirstName>
					<LastName>کیانی ده کیانی</LastName>
<Affiliation>گروه مهندسی بیوسیستم، دانشگاه شهید چمران اهواز</Affiliation>

</Author>
</AuthorList>
				<PublicationType>Journal Article</PublicationType>
			<History>
				<PubDate PubStatus="received">
					<Year>2024</Year>
					<Month>05</Month>
					<Day>05</Day>
				</PubDate>
			</History>
		<Abstract>&lt;strong&gt;Background &amp; Objectives:&lt;/strong&gt; One of the accessible renewable energy sources in all parts of the world is surface geothermal energy. The objective of this experiment was evaluation the effect of the type of air circulation and soil moisture around the air transmission pipe on the output air temperature, efficiency and coefficient of performance (COP) of a shallow geothermal system in the cooling of greenhouse.&lt;br /&gt;&lt;strong&gt; &lt;/strong&gt;&lt;br /&gt;&lt;strong&gt;Materials and Methods:&lt;/strong&gt; A split plot experiment in the form of randomized complete blocks was conducted in a experimental greenhouses located in Arak region in four replications, from July to August 2022. The main plots were the soil moisture contents around the air transmission pipe at two levels of 25% and 10%, and sub plots were two types of air circulation, including open loop and closed loop. A centrifugal fan with a power of 760 watts was used for air circulation. Air circulation was open one day and closed the next. Using a single-channel data logger, the ambient temperature and air temperature entering and exiting the system were recorded and stored at 10-minute intervals. Efficiency and coefficient of performance were calculated during the hottest hours of the day. Finally, analysis of variance of the effect of experimental factors on dependent factors, and comparison of means were performed using MSTAT-C software.&lt;br /&gt;&lt;strong&gt; &lt;/strong&gt;&lt;br /&gt;&lt;strong&gt;Results:&lt;/strong&gt; According to the results, the effect of soil moisture content on the variables of system outlet air temperature, COP and efficiency was significant. Also, although the effect of the air circulation method (closed or open circuit) on the outlet air temperature was not significant, it significantly affected the coefficient of performance and efficiency. The interaction effect of these two independent variables was not significant on any of the dependent variables. The temperature of the fan inlet air (ambient air) during hot hours of the day had no effect on the fan outlet air temperature. Therefore, the use of the system is recommended both in temperate regions (central regions of the country) and in very hot regions (southern regions of the country). In the closed-loop method, with an increase in the difference between the inlet and outlet air temperatures of the system, the amount of power produced and the coefficient of performance of the system are greater compared to the open-loop method.&lt;br /&gt;&lt;strong&gt; &lt;/strong&gt;&lt;br /&gt;&lt;strong&gt;Conclusion: &lt;/strong&gt;The higher the ambient air temperature, the higher the COP and efficiency of the system. As soil moisture around the air transmission pipe increases, the output temperature of the system decreases. Therefore, the efficiency and COP of the system increases.&lt;br /&gt;&lt;strong&gt; &lt;/strong&gt;</Abstract>
			<OtherAbstract Language="FA">&lt;strong&gt;مقدمه و اهداف:&lt;/strong&gt;&lt;strong&gt; &lt;/strong&gt;&lt;strong&gt; &lt;/strong&gt;یکی از منابع انرژی قابل‏دسترس در تمام نقاط دنیا، انرژی گرما‏زمینی سطحی می‏باشد&lt;strong&gt;. &lt;/strong&gt;هدف از انجام این آزمیش، ارزیابی تاثیر نحوه چرخش هوا و مقدار رطوبت  خاک اطراف لوله انتقال هوا بر دمای هوای خروجی، راندمان و ضریب عملکرد یک سامانه زمین گرمایی سطحی در سرمایش گلخانه بود&lt;strong&gt;. &lt;/strong&gt;&lt;br /&gt;&lt;strong&gt; &lt;/strong&gt;&lt;br /&gt;&lt;strong&gt;مواد و روش‏ها:&lt;/strong&gt; آزمایش به صورت کرت‏های خرد‏شده در قالب طرح بلوک‏های کامل‏ تصادفی در چهار تکرار در تیر و مرداد 1401 در یک گلخانه تحقیقاتی از نوع تونلی قوسی مجهز به تجهیزات زمین‌گرمایی در شهر اراک انجام شد. هیچ‏گونه سامانه سرمایشی دیگری در این آزمایش استفاده نشد. رطوبت خاک اطراف لوله در دو سطح 10 و 25 درصد، به عنوان کرت اصلی  و دو نوع چرخش هوای حلقه باز و بسته، به عنوان کرت فرعی در نظر گرفته شد.  برای چرخش هوا، از فن گریز از مرکز با توان 760 وات استفاده شد. چرخش هوا یک روز به صورت باز و روز دیگر به صورت بسته بود. با استفاده از یک دیتالاگر تک‏کاناله، دمای محیط و هوای ورودی به گلخانه به فواصل زمانی هر 10 دقیقه، ثبت و ذخیره می‏شد. راندمان و ضریب عملکرد در گرم‏ترین ساعات روز اندازه‏گیری و محاسبه شد. در نهایت آنالیز واریانس تاثیر عامل‏های آزمایش بر روی صفات اندازه‏گیری شده و همچنین مقایسه میانگین‏ها با استفاده از نرم‏افزار  MSTAT-C انجام شد.&lt;br /&gt;&lt;strong&gt; &lt;/strong&gt;&lt;br /&gt;&lt;strong&gt;نتایج&lt;/strong&gt;: با توجه به نتایج، اثر میزان رطوبت خاک بر متغیرهای دمای هوای خروجی سامانه، ضریب عملکرد و راندمان معنی­دار بود. همچنین با این که اثر نحوه چرخش هوا (حلقه بسته یا باز) بر میزان دمای هوای خروجی معنی­دار نبود، اما بر ضریب عملکرد و راندمان معنی­دار بود. اثر متقابل این دو متغیر مستقل بر هیچ کدام از متغیرهای وابسته معنی­دار نبود. دمای هوای ورودی فن (هوای محیط) در ساعات گرم روز، تاثیری بر روی دمای هوای خروجی فن نداشت. بنابراین، استفاده از سامانه، هم در مناطق معتدل (مناطق مرکزی کشور) و هم در مناطق بسیار‏‏گرم (مناطق جنوبی کشور) قابل‏توصیه می‏باشد. در روش حلقه‏بسته با افزایش اختلاف دمای هوای ورودی و خروجی سامانه، مقدار توان تولید‏شده و مقدارضریب عملکرد سامانه در مقایسه با روش حلقه باز بیشتر می­باشد.&lt;strong&gt; &lt;/strong&gt;&lt;br /&gt;&lt;strong&gt;یافته ‏ها:&lt;/strong&gt; با افزایش دمای هوای ورودی، ضریب عملکرد و راندمان سامانه افزایش می یابد. با افزایش رطوبت خاک، دمای هوای خروجی سامانه کاهش می یابد که به دنبال آن، راندمان و ضریب عملکرد سامانه افزایش می‏یابد.  </OtherAbstract>
		<ObjectList>
			<Object Type="keyword">
			<Param Name="value">انرژی‌های تجدیدپذیر</Param>
			</Object>
			<Object Type="keyword">
			<Param Name="value">پایداری</Param>
			</Object>
			<Object Type="keyword">
			<Param Name="value">پمپ حرارتی زمین- هوا</Param>
			</Object>
			<Object Type="keyword">
			<Param Name="value">گرما‏زمینی‏ سطحی</Param>
			</Object>
			<Object Type="keyword">
			<Param Name="value">پیش سرمایش</Param>
			</Object>
		</ObjectList>
<ArchiveCopySource DocType="pdf">https://sustainagriculture.tabrizu.ac.ir/article_21388_e0e83abada308894bd34ea8abe6aa58e.pdf</ArchiveCopySource>
</Article>